Practice note 04: MRI

MRI machine financing, and how much of an MRI is really the machine

An MRI quote is a system price plus a building project. Lenders treat the two halves very differently, so plan them separately from the start.

Summary

MRI machine financing pays for the scanner and its components on fixed monthly payments over terms up to 84 months, with the system as collateral. Provide Capital Finance finances MRI up to $5,000,000 per transaction, new or refurbished. How much an MRI machine costs depends on field strength, condition and above all the siting work, much of which is construction rather than equipment.

How much is an MRI machine?

Anyone searching that question usually wants a number, and the honest reply is that the number on the system quote is only part of what you will spend. We do not publish price ranges, because they would describe someone else's project. What we can do is set out the parts of the total, so the quotes you collect can be read properly.

The system price itself is moved by field strength (1.5T and 3T are the common clinical choices, with lower-field and extremity systems for specific uses), by new against refurbished, by the coil set, and by the software options for the studies you plan to run. Then comes the room.

What is in an MRI suite, apart from the magnet?

Fig. 1. Schematic MRI suite plan showing the four safety zones, RF shield and equipment roomSchematic floor plan. Zone I is the public corridor. Zone II holds reception, changing and safety screening. Zone III is the control room with a window into the magnet room, open only to screened people under MR staff control. Zone IV is the magnet room inside the radiofrequency shield, with the magnet, the patient table, a dashed fringe field line and a quench vent to the outside. An equipment room beside the control room holds the gradient and RF cabinets, the chiller and power distribution.OFFICESReading room, storageZONE IVMagnet room,inside RF shieldTableDashed: fringefield lineQuench ventto outsideZONE IIReception, changing,MR safety screeningZONE IIIControl room. Screenedpeople only, underMR staff controlEQUIPMENT ROOMGradient and RF cabinets,chiller, power distributionwindowZONE IPublic corridor, free accessZones follow the four-zone concept in the ACR Manual on MR Safety. Schematic, not to scale.
Fig. 1. A schematic MRI suite organized by the four safety zones of the ACR Manual on MR Safety. The radiofrequency shield encloses Zone IV; the equipment room holds the cabinets and the chiller that the system needs to run. Every item outside the magnet itself is a siting cost of some kind.Drawing: Provide Capital Finance, after the ACR four-zone concept.

The four zones are a safety concept, but they are a good map of the budget too. Zone IV needs RF shielding around the whole room, often magnetic shielding where the fringe field would reach somewhere it should not, a quench vent for superconducting magnets, and a floor that can take the weight. Zone III needs a control room with a sightline to the patient. The equipment room needs power, cooling and space for the gradient and RF cabinets. And something has to get a magnet weighing several tons into the building: that is rigging, and sometimes a crane and an opened wall.

Which parts of an MRI project can an equipment lender finance?

A lender can recover a magnet. It cannot recover a shielded wall. That one fact sorts most MRI budgets into two piles.

Table 1. Typical MRI project lines and how they are usually funded
LineUsually billed byIn an equipment deal?
Magnet, gantry, table, coilsManufacturer or resellerYes, this is the core collateral
Gradient and RF cabinets, console, workstationManufacturer or resellerYes
Chiller and system coolingManufacturer, or a mechanical contractorOften, when billed with the system
Software options and post-processingManufacturerOften, when part of the system quote
Rigging and deliveryRigging company, often arranged by the vendorSometimes, when on the vendor's invoice
RF shielding (the cage)Shielding specialistCase by case; ask early
Magnetic shielding, floor work, quench ventContractorRarely. Usually construction financing or cash
Walls, finishes, HVAC, electrical serviceGeneral contractorNo. Landlord allowance, construction loan or cash
Service contractManufacturer or independent service organizationUsually kept separate

The column on the right is the one to settle before you sign anything with a vendor, because it decides how much cash or other financing the project needs beyond the equipment deal. Bring every quote at once and we will tell you which lines we can include.

Is a refurbished MRI a sensible purchase?

For many outpatient centers, yes. Refurbished MRI is an established market, and the questions are the ones that apply to any refurbished imaging: who did the work, what warranty and service come with it, how long the manufacturer will keep supporting the platform, and the condition of the magnet and the helium system. A unit moved from another site has to be ramped down, transported and ramped up again, which is a specialist job with its own cost. Our note on refurbished medical equipment financing has an inspection record you can take to the seller.

How should payments line up with the build?

MRI projects run on the construction calendar. The system may be ordered months before the room is ready, delivered into a finished shield, installed, tested and accepted, and only then used on patients. Plan the financing around that sequence:

  1. Approval earlyGet the equipment financing approved while the room is still on paper. A soft pull costs nothing and tells you what the deal looks like.
  2. Vendor depositSome vendors ask for a deposit with the order. Tell us at the start if yours does, so it can be planned for.
  3. Delivery and installationThe magnet is rigged in, connected and brought to field.
  4. AcceptanceThe system passes acceptance testing. The vendor is paid and the payment schedule set in your agreement begins.
Example, illustrative only, not a quote

An imaging group budgets an MRI room with a refurbished 1.5T system. Of its quotes, $1,180,000 covers the system, coils, cabinets, chiller, rigging and installation from the reseller, and $410,000 covers the RF cage, the floor, the quench vent and the room build-out. The first figure is a natural equipment financing request, written as one agreement. Over 84 months, before any finance charge, $1,180,000 ÷ 84 = $14,047.62 a month in principal. The construction figure is funded through the group's bank line and its landlord's improvement allowance.

What to have ready

  1. The system quote, with coils and software listed
  2. Siting, rigging and shielding quotes, even if they will be paid elsewhere
  3. The project schedule, with the expected acceptance date
  4. Two years of business tax returns and recent financial statements
  5. The lease for the space, or confirmation of ownership

Planning an MRI room?

Start with the equipment approval, while the drawings are still being revised. Nine questions and a soft pull.

MRI financing questions

Can an MRI project above $5,000,000 be financed?

Our limit is $5,000,000 per transaction. A larger project may be split, for example the system in one agreement and other imaging equipment in another, with the construction funded separately.

Can you finance an open or extremity MRI?

Yes. Open, upright and extremity systems are financed the same way as conventional closed-bore units. Their siting needs are often lighter, which simplifies the budget.

Does the helium refill count as equipment?

The first fill delivered with the system is part of its cost. Later refills and service visits are operating expenses.

References

  1. American College of Radiology. ACR Manual on MR Safety, which sets out the four-zone access concept for MR suites.
  2. Internal Revenue Service. Publication 946, for depreciation and Section 179. Ask your tax advisor.